...Inaktivitäts-Timeout bei den Eingabehilfen auslesen/setzen?
Autor: Thomas Stutz
{
Retrieves information about the time-out period associated
with the accessibility features.
The pvParam parameter must point to an ACCESSTIMEOUT
structure that receives the information.
Set the cbSize member of this structure and the
uiParam parameter to SizeOf(ACCESSTIMEOUT).
}
{
Ermittelt die maximale Zeit wo der Benutzer keine Eingaben macht bei den
Eingabehilfen. "uiParam" muss die Größe der Struktur
ACCESSTIMEOUT sein und "pvParam" muss eine ACCESSTIMEOUT-Struktur
übergeben werden, die gefüllt wird.
}
// ACCESSTIMEOUT structure
type
TAccessTimeOut = record
cbSize: UINT;
dwFlags: DWORD;
iTimeOutMSec: DWORD;
end;
procedure GetAccessTimeOut(var bTimeOut: Boolean; var bFeedBack: Boolean;
var iTimeOutTime: Integer);
// bTimeOut: the time-out period for accessibility features.
// bFeedBack: the operating system plays a descending
// siren sound when the time-out period elapses and the
// Accessibility features are turned off.
// iTimeOutTime: Timeout in ms
var
AccessTimeOut: TAccessTimeOut;
begin
ZeroMemory(@AccessTimeOut, SizeOf(TAccessTimeOut));
AccessTimeOut.cbSize := SizeOf(TAccessTimeOut);
SystemParametersInfo(SPI_GETACCESSTIMEOUT, SizeOf(AccessTimeOut), @AccessTimeOut, 0);
bTimeOut := (AccessTimeOut.dwFlags and ATF_TIMEOUTON) = ATF_TIMEOUTON;
bFeedBack := (AccessTimeOut.dwFlags and ATF_ONOFFFEEDBACK) = ATF_ONOFFFEEDBACK;
iTimeOutTime := AccessTimeOut.iTimeOutMSec;
end;
// Test it:
procedure TForm1.Button2Click(Sender: TObject);
var
bTimeOut, bFeedBack: Boolean;
iTimeOutTime: Integer;
begin
GetAccessTimeOut(bTimeOut, bFeedBack, iTimeOutTime);
label1.Caption := IntToStr(Ord(bTimeOut));
Label2.Caption := IntToStr(Ord(bFeedBack));
Label3.Caption := IntToStr(iTimeOutTime);
end;
{
Sets the time-out period associated with the accessibility features.
The pvParam parameter must point to anACCESSTIMEOUT structure that
contains the new parameters.
Set the cbSize member of this structure and the uiParam
parameter to sizeof(ACCESSTIMEOUT).
}
{
Setzt Informationen zu den ACCESSEDTIMEOUT-Eigenschaften.
"uiParam" erwartet die Größe der ACCESSEDTIMEOUT-Struktur,
die in "pvParam" übergeben werden muss.
}
procedure SetAccessTimeOut(bTimeOut, bFeedBack: Boolean; iTimeOutTime: Integer);
// bTimeOut: If true, a time-out period has been set for accessibility features.
// bFeedBack: If true, the operating system plays a descending
// siren sound when the time-out period elapses and the
// accessibility features are turned off.
// iTimeOutTime: Timeout in ms
var
AccessTimeOut: TAccessTimeOut;
begin
ZeroMemory(@AccessTimeOut, SizeOf(TAccessTimeOut));
AccessTimeOut.cbSize := SizeOf(TAccessTimeOut);
case bTimeOut of
True: AccessTimeOut.dwFlags := ATF_TIMEOUTON;
False: AccessTimeOut.dwFlags := 0;
end;
if bFeedBack then
AccessTimeOut.dwFlags := AccessTimeOut.dwFlags or ATF_ONOFFFEEDBACK;
AccessTimeOut.iTimeOutMSec := iTimeOutTime;
SystemParametersInfo(SPI_SETACCESSTIMEOUT, SizeOf(AccessTimeOut),
@AccessTimeOut, SPIF_UPDATEINIFILE or SPIF_SENDWININICHANGE);
end;
// Test it:
procedure TForm1.Button1Click(Sender: TObject);
begin
SetAccessTimeOut(True, True, 600000); // 10 min. timeout
end;
printed from
www.swissdelphicenter.ch
developers knowledge base